The words you'll see on estimates, equipment labels and PG&E bills — and where to read more about each one.

A2L refrigerant
A class of lower-global-warming refrigerants, such as R-454B and R-32, that newer air conditioners and heat pumps use in place of R-410A. They are rated mildly flammable, so they come with their own installation and service rules. The refrigerant change, explained
AFUE
Annual Fuel Utilization Efficiency. The share of a furnace's fuel that becomes heat for your home over a typical year. A higher AFUE means less fuel goes up the flue. It does not count heat lost from leaky ducts. What AFUE means
AHJ (authority having jurisdiction)
The city, town or county building department that issues permits and inspects work at your address. In our area that can be a city, the Town of Paradise, or Butte, Glenn or Tehama County. Permits for HVAC and solar
Air handler
The indoor cabinet that holds the blower and, often, the cooling coil. It moves conditioned air through your ducts. Heat pump systems and many ductless systems use an air handler instead of a furnace. How heat pumps work
Annual true-up
The once-a-year PG&E statement for solar customers that settles the energy you exported against the energy you used over twelve months. Some households owe money at true-up; others see a small credit. Your PG&E true-up bill, explained
Battery storage
A home battery, such as a Tesla Powerwall, Enphase, SolarEdge or Franklin system, that stores electricity for later use or for backup when the grid goes down. Do you need a battery with solar?
BTU
British Thermal Unit. The amount of heat needed to raise one pound of water by one degree Fahrenheit. Heating and cooling equipment is sized in BTUs per hour; 12,000 BTU per hour equals one ton of cooling. Air conditioning installation
Carbon monoxide (CO)
An odorless, colorless gas produced when fuel burns. A cracked heat exchanger or a blocked flue can let it into the home, which is why fuel-burning homes need working CO alarms. Furnace carbon monoxide safety
Compressor
The pump in the outdoor unit that pressurizes refrigerant so it can carry heat. It is one of the most expensive parts of a system, which often tips a repair-or-replace decision. Repair or replace your AC?
Condenser (outdoor unit)
The outdoor half of a split air conditioner or heat pump. It holds the compressor and a fan that releases the heat pulled out of your home. Why is my AC blowing warm air?
Dual fuel
A system that pairs a heat pump with a gas furnace and switches between them, using the heat pump in milder weather and the furnace when it is colder or when gas is cheaper to run. Heat pump vs furnace and AC
Duct leakage
Conditioned air that escapes through gaps and loose joints in ductwork, often into a hot attic. In California some HVAC alterations require a third-party test of duct leakage. What a home energy audit looks at
Ductless mini-split
A heat pump that sends refrigerant through a small line set to one or more indoor heads mounted on walls or ceilings, with no ductwork. Each head can be controlled as its own zone. Ductless vs central air
EER2
Energy Efficiency Ratio, measured under the newer test procedure. It rates cooling efficiency at a single hot outdoor condition, which matters in hot climates like the Sacramento Valley. SEER2 and efficiency ratings
Evaporator coil
The indoor coil, usually on top of the furnace or inside the air handler, where refrigerant absorbs heat from the air. A dirty or frozen coil is a common reason for weak cooling. Why is my AC blowing warm air?
Heat exchanger
The metal chamber inside a gas furnace that keeps combustion gases separate from the air you breathe. Cracks are a safety concern and a common reason a furnace is replaced. Furnace carbon monoxide safety
Heat pump
An electric system that moves heat instead of making it: out of the house in summer and into the house in winter. One outdoor unit handles both heating and cooling. How heat pumps work
Heat pump water heater (HPWH)
A water heater that uses heat pump technology to pull heat from the surrounding air into the tank, using far less electricity than a standard electric resistance tank. Heat pump water heaters
HERS verification
Testing by an independent Home Energy Rating System rater, separate from your contractor and the inspector. California's energy code requires it for some HVAC alterations, for example duct leakage testing. Permits for HVAC and solar
HSPF2
Heating Seasonal Performance Factor under the newer test procedure. It rates a heat pump's heating efficiency over a season; higher is more efficient. SEER2 and efficiency ratings
Interconnection
The utility's approval to connect a solar or battery system to the grid. With PG&E it is a separate step from the local building inspection. Solar installation
Inverter
In solar, the device that converts the panels' direct current into the alternating current your home uses. In HVAC, an inverter-driven compressor varies its speed instead of switching fully on and off. Solar maintenance and monitoring
kW and kWh
A kilowatt (kW) is a rate of power; a kilowatt-hour (kWh) is energy used over time. Your PG&E bill charges by kWh; solar systems and batteries are described by both. Do you need a battery with solar?
Level 2 charger
An electric vehicle charger that runs on a 240-volt circuit and charges much faster than plugging into a standard outlet. EV charging at home
Line set
The pair of copper refrigerant lines that connect the outdoor unit to the indoor coil or mini-split heads. Mini-splits for garages and additions
Load calculation
A room-by-room estimate of how much heating and cooling a house needs, based on its size, insulation, windows, orientation and ducts. It is how equipment is sized correctly instead of by rule of thumb. What to expect from an estimate
MERV
Minimum Efficiency Reporting Value. A 1–16 rating of how well an air filter captures particles. Higher MERV filters catch smaller particles but can restrict airflow if the system isn't built for them. Which MERV filter to use
Net Billing Tariff (NBT)
The current California solar billing structure for newer PG&E solar customers. It credits exported energy on a separate value schedule, which changes how much a battery is worth. Your PG&E true-up bill, explained
Net energy metering (NEM)
The older California solar billing structure, still in place for many existing systems, which credits exported energy closer to the retail rate. Your PG&E true-up bill, explained
Power Purchase Agreement (PPA)
A solar arrangement where a third-party provider owns and maintains the system on your roof and you buy the power it produces, instead of buying the equipment. Solar PPA vs buying solar
PSPS (Public Safety Power Shutoff)
A planned PG&E power shutoff during high fire-risk weather. Batteries and generators are the two common ways to keep essential circuits running through one. Battery vs generator for backup power
R-410A
The refrigerant used in most air conditioners and heat pumps installed over roughly the last two decades. Federal rules are moving new equipment to lower-impact A2L refrigerants. The refrigerant change, explained
SEER2
Seasonal Energy Efficiency Ratio under the newer test procedure. It rates cooling efficiency over a typical season; higher is more efficient. SEER2 numbers read lower than old SEER numbers for the same equipment. SEER2 and efficiency ratings
SGIP
California's Self-Generation Incentive Program, run through the CPUC, which has offered incentives for home battery storage. Availability and eligibility change; ask us what applies today. Rebates and incentives
Short cycling
When a system turns on and off in short bursts instead of running full cycles. Common causes are oversizing, a dirty filter, low refrigerant or a thermostat problem. AC repair and service
Static pressure
The resistance to airflow in your ducts and filter. Too much, often from undersized returns or a very dense filter, makes the blower work harder and can hurt comfort and equipment life. Which MERV filter to use
TECH Clean California
A statewide program that offers incentives for heat pumps and heat pump water heaters through enrolled contractors. Climate & Energy Solutions is a TECH-enrolled contractor. Heat pump rebates in Chico
Title 24
California's Building Energy Efficiency Standards (Title 24, Part 6), maintained by the California Energy Commission. It sets energy rules for new construction and for alterations such as HVAC changeouts. Permits for HVAC and solar
Ton (of cooling)
A unit of cooling capacity equal to 12,000 BTU per hour. Homes are not sized by square footage alone; a load calculation sets the right tonnage. What to expect from an estimate
Two-stage and variable-speed
Equipment that can run at a lower output most of the time and ramp up only when needed. It usually gives steadier temperatures, quieter operation and better humidity control than single-stage equipment. What AFUE means
Whole-house fan
A ceiling fan that pulls cool evening air in through open windows and pushes hot air out through the attic. In the North Valley it can cut AC run time on summer nights. Are whole-house fans worth it?